<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Safety devices - Unival</title>
	<atom:link href="https://univalsrl.it/en/product-category/components-for-water-heaters/safety-devices/feed/" rel="self" type="application/rss+xml" />
	<link>https://univalsrl.it/en/product-category/components-for-water-heaters/safety-devices/</link>
	<description>Unique Value for You</description>
	<lastBuildDate>Thu, 14 Oct 2021 09:45:24 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	

<image>
	<url>https://univalsrl.it/wp-content/uploads/2021/08/cropped-Fav-icon-32x32.png</url>
	<title>Safety devices - Unival</title>
	<link>https://univalsrl.it/en/product-category/components-for-water-heaters/safety-devices/</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>Safety device &#8220;simple closed&#8221;, all in PA6 = PC</title>
		<link>https://univalsrl.it/en/product/safety-device-simple-closed-in-pc/</link>
		
		<dc:creator><![CDATA[Enrico Sala]]></dc:creator>
		<pubDate>Fri, 03 Sep 2021 08:57:15 +0000</pubDate>
				<guid isPermaLink="false">http://univalsrl.it/safety-device-simple-closed-all-in-pa6-pc/</guid>

					<description><![CDATA[<p>Function The pressure relief valves protect hot water storage heaters from internal overpressure. Furthermore, they restrict or prevent (according to requirements) water returning to main supply piping. Pressure relief valves essentially consist of 8 main devices: 3 controlling flow and 5 safety devices. The combination of these devices permits realisation which will satisfy customer&#8217;s requirements. [&#8230;]</p>
<p>L'articolo <a href="https://univalsrl.it/en/product/safety-device-simple-closed-in-pc/">Safety device &#8220;simple closed&#8221;, all in PA6 = PC</a> proviene da <a href="https://univalsrl.it/en/">Unival</a>.</p>
]]></description>
										<content:encoded><![CDATA[		<div data-elementor-type="product-post" data-elementor-id="5539" class="elementor elementor-5539 elementor-1758" data-elementor-post-type="product">
						<section class="elementor-section elementor-top-section elementor-element elementor-element-7139e3f2 elementor-section-boxed elementor-section-height-default elementor-section-height-default" data-id="7139e3f2" data-element_type="section">
						<div class="elementor-container elementor-column-gap-default">
					<div class="elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-362bb32a" data-id="362bb32a" data-element_type="column">
			<div class="elementor-widget-wrap elementor-element-populated">
						<div class="elementor-element elementor-element-bae392e elementor-widget elementor-widget-text-editor" data-id="bae392e" data-element_type="widget" data-widget_type="text-editor.default">
				<div class="elementor-widget-container">
							<h2>Function</h2>
<p>The pressure relief valves protect hot water storage heaters from internal overpressure. Furthermore, they restrict or prevent (according to requirements) water returning to main supply piping. Pressure relief valves essentially consist of 8 main devices: 3 controlling flow and 5 safety devices. The combination of these devices permits realisation which will satisfy customer&#8217;s requirements.</p>
<h2>Safety devices</h2>
<h4>&nbsp;&nbsp;&nbsp;&nbsp;1. Water flow control device</h4>
<p>This device controls and runs passage of water from inlet source to water heater when <strong>on it’s inside the pressure become lower for 0,1±</strong><strong>0,2 bar (0,01&nbsp;</strong>±<strong>0,02 MPa),</strong> and in the same time it runs or pre vent water to go back into inlet source <strong>when the pressure inside water heater become higher for 0,8±</strong><strong>1,5 bar (0,08±</strong><strong>0,15 MPa)</strong>.</p>
<h4>&nbsp;&nbsp;&nbsp;&nbsp;2. Discharge pressure device ( Safety )</h4>
<p>The function of discharge pressure device is to avoid excessive pressure increment inside water heater. Calibration setting of discharge device is reached by compression of a spring to the standard <strong>value of opening 8,5 bar with tolerance ± 1 (0,85 MPa ±0,1)</strong>. This <strong>value can vary and</strong> <strong>be set according to the client&#8217;s request</strong>. The device is sealed with disc to prevent from tampering. Should the seal be removed and the setting altered the maximum opening won&#8217;t be higher than 12 bar (1,2 MPa). During the testing the value of calibration setting is took on the second opening of discharge pressure device. During the phase of discharge, <strong>device becomes again watertight when the pressure decreases for 1 bar (0,1 MPa) in respect of standard opening value 8,5 bar</strong> <strong>±1</strong>(<strong>0,85 MPa</strong><strong>±</strong><strong>0,1).</strong> All valves are calibrated and tested automatically before being packed and we guaranty high quality standards constant in quantities and time.</p>
<h4>Valve body</h4>
<p>The body is made of hot moulded BRASS UNI EN 12165CW617N. Direction of the water flow. The surface is nickel &#8211; plated. Available (according to type) with threaded connections: 1/2 &#8221; -3/4 &#8221; -1 &#8221; Gas. The valve body is designed to withstand internal pressure up to 16 bar (±1,6MPa). <strong>Maximum working temperature of the assembled valve: 120° C.</strong> The valve is automatically calibrated and checked during assembling. Further testing in percentage is carried out once assembling is finished.</p>
						</div>
				</div>
					</div>
		</div>
					</div>
		</section>
				</div>
		<p>L'articolo <a href="https://univalsrl.it/en/product/safety-device-simple-closed-in-pc/">Safety device &#8220;simple closed&#8221;, all in PA6 = PC</a> proviene da <a href="https://univalsrl.it/en/">Unival</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Safety device &#8220;simple closed&#8221;, all brass= SK</title>
		<link>https://univalsrl.it/en/product/safety-device-simple-closed-brass-sk/</link>
		
		<dc:creator><![CDATA[Enrico Sala]]></dc:creator>
		<pubDate>Fri, 03 Sep 2021 08:34:41 +0000</pubDate>
				<guid isPermaLink="false">http://univalsrl.it/safety-device-simple-closed-all-brass-sk/</guid>

					<description><![CDATA[<p>Function The pressure relief valves protect hot water storage heaters from internal overpressure. Furthermore, they restrict or prevent (according to requirements) water returning to main supply piping. Pressure relief valves essentially consist of 8 main devices: 3 controlling flow and 5 safety devices. The combination of these devices permits realisation which will satisfy customer&#8217;s requirements. [&#8230;]</p>
<p>L'articolo <a href="https://univalsrl.it/en/product/safety-device-simple-closed-brass-sk/">Safety device &#8220;simple closed&#8221;, all brass= SK</a> proviene da <a href="https://univalsrl.it/en/">Unival</a>.</p>
]]></description>
										<content:encoded><![CDATA[		<div data-elementor-type="product-post" data-elementor-id="5534" class="elementor elementor-5534 elementor-1756" data-elementor-post-type="product">
						<section class="elementor-section elementor-top-section elementor-element elementor-element-5e87397e elementor-section-boxed elementor-section-height-default elementor-section-height-default" data-id="5e87397e" data-element_type="section">
						<div class="elementor-container elementor-column-gap-default">
					<div class="elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-7c4ac94d" data-id="7c4ac94d" data-element_type="column">
			<div class="elementor-widget-wrap elementor-element-populated">
						<div class="elementor-element elementor-element-cfd84ac elementor-widget elementor-widget-text-editor" data-id="cfd84ac" data-element_type="widget" data-widget_type="text-editor.default">
				<div class="elementor-widget-container">
							<h2>Function</h2>
<p>The pressure relief valves protect hot water storage heaters from internal overpressure. Furthermore, they restrict or prevent (according to requirements) water returning to main supply piping. Pressure relief valves essentially consist of 8 main devices: 3 controlling flow and 5 safety devices. The combination of these devices permits realisation which will satisfy customer&#8217;s requirements.</p>
<h2>Safety devices</h2>
<h4>&nbsp;&nbsp;&nbsp;&nbsp;1. Water flow control device</h4>
<p>This device controls and runs passage of water from inlet source to water heater when <strong>on it’s inside the pressure become lower for 0,1±</strong><strong>0,2 bar (0,01&nbsp;</strong>±<strong>0,02 MPa),</strong> and in the same time it runs or pre vent water to go back into inlet source <strong>when the pressure inside water heater become higher for 0,8</strong>±<strong>1,5 bar (0,08±</strong><strong>0,15 MPa)</strong>.</p>
<h4>&nbsp;&nbsp;&nbsp;&nbsp;2. Discharge pressure device ( Safety )</h4>
<p>The function of discharge pressure device is to avoid excessive pressure increment inside water heater. Calibration setting of discharge device is reached by compression of a spring to the standard <strong>value of opening 8,5 bar with tolerance ± 1 (0,85 MPa ±0,1)</strong>. This <strong>value can vary and</strong> <strong>be set according to the client&#8217;s request</strong>. The device is sealed with disc to prevent from tampering. Should the seal be removed and the setting altered the maximum opening won&#8217;t be higher than 12 bar (1,2 MPa). During the testing the value of calibration setting is took on the second opening of discharge pressure device. During the phase of discharge,<strong>device becomes again watertight when the pressure decreases for 1 bar (0,1 MPa) in respect of standard opening value 8,5 bar</strong><strong>±1</strong> <strong>(0,85 MPa</strong><strong>±</strong><strong>0,1</strong>). All valves are calibrated and tested automatically before being packed and we guaranty high quality standards constant in quantities and time.</p>
<h4>Valve body</h4>
<p>The body is made of hot moulded BRASS UNI EN 12165CW617N. Direction of the water flow. The surface is nickel &#8211; plated. Available (according to type) with threaded connections: 1/2 &#8221; -3/4 &#8221; -1 &#8221; Gas. The valve body is designed to withstand internal pressure up to 16 bar (±1,6MPa). <strong>Maximum working temperature of the assembled valve: 120° C.</strong> The valve is automatically calibrated and checked during assembling. Further testing in percentage is carried out once assembling is finished.</p>
						</div>
				</div>
					</div>
		</div>
					</div>
		</section>
				</div>
		<p>L'articolo <a href="https://univalsrl.it/en/product/safety-device-simple-closed-brass-sk/">Safety device &#8220;simple closed&#8221;, all brass= SK</a> proviene da <a href="https://univalsrl.it/en/">Unival</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Double safety device &#8220;open&#8221;, disc in PA6, brass plunger= PD</title>
		<link>https://univalsrl.it/en/product/double-safety-device-open-disc-brass-plunger-pd/</link>
		
		<dc:creator><![CDATA[Enrico Sala]]></dc:creator>
		<pubDate>Fri, 03 Sep 2021 08:27:46 +0000</pubDate>
				<guid isPermaLink="false">http://univalsrl.it/double-safety-device-open-disc-in-pa6-brass-plunger-pd/</guid>

					<description><![CDATA[<p>Function The pressure relief valves protect hot water storage heaters from internal overpressure. Furthermore, they restrict or prevent (according to requirements) water returning to main supply piping. Pressure relief valves essentially consist of 8 main devices: 3 controlling flow and 5 safety devices. The combination of these devices permits realisation which will satisfy customer&#8217;s requirements. [&#8230;]</p>
<p>L'articolo <a href="https://univalsrl.it/en/product/double-safety-device-open-disc-brass-plunger-pd/">Double safety device &#8220;open&#8221;, disc in PA6, brass plunger= PD</a> proviene da <a href="https://univalsrl.it/en/">Unival</a>.</p>
]]></description>
										<content:encoded><![CDATA[		<div data-elementor-type="product-post" data-elementor-id="5529" class="elementor elementor-5529 elementor-1792" data-elementor-post-type="product">
						<section class="elementor-section elementor-top-section elementor-element elementor-element-38a63ca8 elementor-section-boxed elementor-section-height-default elementor-section-height-default" data-id="38a63ca8" data-element_type="section">
						<div class="elementor-container elementor-column-gap-default">
					<div class="elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-71a9f751" data-id="71a9f751" data-element_type="column">
			<div class="elementor-widget-wrap elementor-element-populated">
						<div class="elementor-element elementor-element-a3d9925 elementor-widget elementor-widget-text-editor" data-id="a3d9925" data-element_type="widget" data-widget_type="text-editor.default">
				<div class="elementor-widget-container">
							<h2>Function</h2>
<p>The pressure relief valves protect hot water storage heaters from internal overpressure. Furthermore, they restrict or prevent (according to requirements) water returning to main supply piping. Pressure relief valves essentially consist of 8 main devices: 3 controlling flow and 5 safety devices. The combination of these devices permits realisation which will satisfy customer&#8217;s requirements.</p>
<h2>Safety devices</h2>
<h4>&nbsp;&nbsp;&nbsp;&nbsp;1. Water flow control device</h4>
<p>This device controls and runs passage of water from inlet source to water heater when <strong>on it’s inside the pressure become lower for 0,1±</strong><strong>0,2 bar (0,01&nbsp;</strong>±<strong>0,02 MPa),</strong> and in the same time it runs or pre vent water to go back into inlet source <strong>when the pressure inside water heater become higher for 0,8±</strong><strong>1,5 bar (0,08±</strong><strong>0,15 MPa)</strong>.</p>
<h4>&nbsp;&nbsp;&nbsp;&nbsp;2. Discharge pressure device ( Safety )</h4>
<p>The function of discharge pressure device is to avoid excessive pressure increment inside water heater. Calibration setting of discharge device is reached by compression of a spring to the standard <strong>value of opening 8,5 bar with tolerance ± 1 (0,85 MPa ±0,1)</strong>. This <strong>value can vary and</strong> <strong>be set according to the client&#8217;s request</strong>. The device is sealed with disc to prevent from tampering. Should the seal be removed and the setting altered the maximum opening won&#8217;t be higher than 12 bar (1,2 MPa). During the testing the value of calibration setting is took on the second opening of discharge pressure device. During the phase of discharge, <strong>device becomes again watertight when the pressure decreases for 1 bar (0,1 MPa) in respect of standard opening value 8,5</strong> bar <strong>±</strong><strong>1 (0,85 MPa</strong><strong>±</strong><strong>0,1).</strong> All valves are calibrated and tested automatically before being packed and we guaranty high quality standards constant in quantities and time.</p>
<h4>Valve body</h4>
<p>The body is made of hot moulded BRASS UNI EN 12165CW617N. Direction of the water flow. The surface is nickel &#8211; plated. Available (according to type) with threaded connections: 1/2 &#8221; -3/4 &#8221; -1 &#8221; Gas. The valve body is designed to withstand internal pressure up to 16 bar (±1,6MPa). <strong>Maximum working temperature of the assembled valve: 120° C.</strong> The valve is automatically calibrated and checked during assembling. Further testing in percentage is carried out once assembling is finished.</p>
						</div>
				</div>
					</div>
		</div>
					</div>
		</section>
				</div>
		<p>L'articolo <a href="https://univalsrl.it/en/product/double-safety-device-open-disc-brass-plunger-pd/">Double safety device &#8220;open&#8221;, disc in PA6, brass plunger= PD</a> proviene da <a href="https://univalsrl.it/en/">Unival</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Double safety device &#8220;open&#8221;, brass disc and brass plunger=PO</title>
		<link>https://univalsrl.it/en/product/double-safety-device-open-brass-disc-brass-plunger-po/</link>
		
		<dc:creator><![CDATA[Enrico Sala]]></dc:creator>
		<pubDate>Fri, 03 Sep 2021 08:20:54 +0000</pubDate>
				<guid isPermaLink="false">http://univalsrl.it/double-safety-device-open-brass-disc-and-brass-plungerpo/</guid>

					<description><![CDATA[<p>Function The pressure relief valves protect hot water storage heaters from internal overpressure. Furthermore, they restrict or prevent (according to requirements) water returning to main supply piping. Pressure relief valves essentially consist of 8 main devices: 3 controlling flow and 5 safety devices. The combination of these devices permits realisation which will satisfy customer&#8217;s requirements. [&#8230;]</p>
<p>L'articolo <a href="https://univalsrl.it/en/product/double-safety-device-open-brass-disc-brass-plunger-po/">Double safety device &#8220;open&#8221;, brass disc and brass plunger=PO</a> proviene da <a href="https://univalsrl.it/en/">Unival</a>.</p>
]]></description>
										<content:encoded><![CDATA[		<div data-elementor-type="product-post" data-elementor-id="5525" class="elementor elementor-5525 elementor-1782" data-elementor-post-type="product">
						<section class="elementor-section elementor-top-section elementor-element elementor-element-38709b03 elementor-section-boxed elementor-section-height-default elementor-section-height-default" data-id="38709b03" data-element_type="section">
						<div class="elementor-container elementor-column-gap-default">
					<div class="elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-789f57d6" data-id="789f57d6" data-element_type="column">
			<div class="elementor-widget-wrap elementor-element-populated">
						<div class="elementor-element elementor-element-9f6fe80 elementor-widget elementor-widget-text-editor" data-id="9f6fe80" data-element_type="widget" data-widget_type="text-editor.default">
				<div class="elementor-widget-container">
							<h2>Function</h2>
<p>The pressure relief valves protect hot water storage heaters from internal overpressure. Furthermore, they restrict or prevent (according to requirements) water returning to main supply piping. Pressure relief valves essentially consist of 8 main devices: 3 controlling flow and 5 safety devices. The combination of these devices permits realisation which will satisfy customer&#8217;s requirements.</p>
<h2>Safety devices</h2>
<h4>&nbsp;&nbsp;&nbsp;&nbsp;1. Water flow control device</h4>
<p>Con questo particolare si controlla e gestisce il transito di acqua dalla rete di alimentazione allo scaldacqua qualora <strong>al suo interno si verifichi una pressione inferiore di 0,1</strong>± <strong>0,2 bar (0,01&nbsp;</strong>± <strong>0,02 MPa),</strong> and in the same time it runs or prevent water to go back into inlet source when the pressure <strong>inside water heater become higher for 0,8</strong>± <strong>1,5 bar (0,08</strong> ± <strong>0,15 MPa)</strong>. </p>
<h4>&nbsp;&nbsp;&nbsp;&nbsp;2. Discharge pressure device ( Safety )</h4>
<p>The function of discharge pressure device is to avoid excessive pressure increment inside water heater. Calibration setting of discharge device is reached by compression of a spring to the standard <strong>value of opening 8,5 bar with tolerance ± 1 (0,85 MPa ±0,1)</strong>. This <strong>value can vary and</strong> <strong>be set according to the client&#8217;s request</strong>. The part is sealed with a disk to prevent tampering, and if the seal is tampered with and adjustment is made, it is not possible to open at pressures higher than 12 bar (1.2 MPa). During the testing the value of calibration setting is took on the second opening of discharge pressure device. During the discharge phase <strong>the device becomes watertight again when the pressure has decreased by 1 bar (0.1 MPa) with respect to the opening value 8.5 bar</strong> <strong>±</strong><strong>1 (0,85 MPa</strong><strong>±</strong><strong>0,1).</strong> All valves are calibrated and tested automatically before being packed and we guaranty high quality standards constant in quantities and time.</p>
<h4>Valve body</h4>
<p>The body is made of hot moulded BRASS UNI EN 12165CW617N. Direction of the water flow. The surface is nickel &#8211; plated. Available (according to type) with threaded connections: 1/2 &#8221; -3/4 &#8221; -1 &#8221; Gas. The valve body is also designed to withstand internal pressures up to 16 bar (1.6 MPa). <strong>Maximum operating temperature of fully assembled valves: 120° C.</strong> The valve is automatically calibrated and checked during assembling. Further testing in percentage is carried out once assembling is finished.</p>
						</div>
				</div>
					</div>
		</div>
					</div>
		</section>
				</div>
		<p>L'articolo <a href="https://univalsrl.it/en/product/double-safety-device-open-brass-disc-brass-plunger-po/">Double safety device &#8220;open&#8221;, brass disc and brass plunger=PO</a> proviene da <a href="https://univalsrl.it/en/">Unival</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Safety device &#8220;open&#8221;, brass disc, plastic, plastic plunger=DO</title>
		<link>https://univalsrl.it/en/product/safety-device-open-brass-disc-plastic-plastic-plunger-do/</link>
		
		<dc:creator><![CDATA[Enrico Sala]]></dc:creator>
		<pubDate>Fri, 03 Sep 2021 08:18:43 +0000</pubDate>
				<guid isPermaLink="false">http://univalsrl.it/safety-device-open-brass-disc-plastic-plastic-plungerdo/</guid>

					<description><![CDATA[<p>Function The pressure relief valves protect hot water storage heaters from internal overpressure. Furthermore, they restrict or prevent (according to requirements) water returning to main supply piping. Le valvole di sicurezza si compongono essenzialmente di 8 dispositivi principali: 3 di controllo del flusso e 5 di sicurezza. La combinazione di questi dispositivi permette di realizzare [&#8230;]</p>
<p>L'articolo <a href="https://univalsrl.it/en/product/safety-device-open-brass-disc-plastic-plastic-plunger-do/">Safety device &#8220;open&#8221;, brass disc, plastic, plastic plunger=DO</a> proviene da <a href="https://univalsrl.it/en/">Unival</a>.</p>
]]></description>
										<content:encoded><![CDATA[		<div data-elementor-type="product-post" data-elementor-id="5520" class="elementor elementor-5520 elementor-1778" data-elementor-post-type="product">
						<section class="elementor-section elementor-top-section elementor-element elementor-element-9f0a748 elementor-section-boxed elementor-section-height-default elementor-section-height-default" data-id="9f0a748" data-element_type="section">
						<div class="elementor-container elementor-column-gap-default">
					<div class="elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-72ae08db" data-id="72ae08db" data-element_type="column">
			<div class="elementor-widget-wrap elementor-element-populated">
						<div class="elementor-element elementor-element-a63e89c elementor-widget elementor-widget-text-editor" data-id="a63e89c" data-element_type="widget" data-widget_type="text-editor.default">
				<div class="elementor-widget-container">
							<h2>Function</h2>
<p>The pressure relief valves protect hot water storage heaters from internal overpressure. Furthermore, they restrict or prevent (according to requirements) water returning to main supply piping. Le valvole di sicurezza si compongono essenzialmente di 8 dispositivi principali: 3 di controllo del flusso e 5 di sicurezza. La combinazione di questi dispositivi permette di realizzare delle valvole atte a soddisfare qualsiasi esigenza da parte del cliente. </p>
<h2>Safety devices</h2>
<h4>&nbsp;&nbsp;&nbsp;&nbsp;1. Water flow control device</h4>
<p>This device controls and runs passage of water from inlet source to water heater when <strong>on it’s inside the pressure become lower for 0,1±</strong><strong>0,2 bar (0,01&nbsp;</strong>±<strong>0,02 MPa),</strong> and in the same time it runs or pre vent water to go back into inlet source <strong>when the pressure inside water heater become higher for 0,8±</strong><strong>1,5 bar (0,08±</strong><strong>0,15 MPa)</strong>.</p>
<h4>2. &nbsp;&nbsp;&nbsp;&nbsp;Discharge pressure device ( Safety )</h4>
<p>The function of discharge pressure device is to avoid excessive pressure increment inside water heater. Calibration setting of discharge device is reached by compression of a spring to the standard <strong>value of opening 8,5 bar with tolerance ± 1 (0,85 MPa ±0,1)</strong>. This <strong>value can vary and</strong> <strong>be set according to the client&#8217;s request</strong>. The part is sealed with a disk to prevent tampering, and if the seal is tampered with and adjustment is made, it is not possible to open at pressures higher than 12 bar (1.2 MPa). During the testing the value of calibration setting is took on the second opening of discharge pressure device. During the discharge phase <strong>the device becomes watertight again when the pressure has decreased by 1 bar (0.1 MPa) with respect to the opening value 8.5 bar</strong> <strong>±</strong> <strong>1(0.85 MPa</strong> <strong>±</strong><strong>0.1).</strong> All valves are calibrated and tested automatically before being packed and we guaranty high quality standards constant in quantities and time.</p>
<h4>Valve body</h4>
<p>The body is made of hot moulded BRASS UNI EN 12165CW617N. Direction of the water flow. The surface is nickel &#8211; plated. Available (according to type) with threaded connections: 1/2 &#8221; -3/4 &#8221; -1 &#8221; Gas. The valve body is also designed to withstand internal pressures up to 16 bar (1.6 MPa). <strong>Maximum operating temperature of fully assembled valves: 120° C.</strong> The valve is automatically calibrated and checked during assembling. Further testing in percentage is carried out once assembling is finished.</p>
						</div>
				</div>
					</div>
		</div>
					</div>
		</section>
				</div>
		<p>L'articolo <a href="https://univalsrl.it/en/product/safety-device-open-brass-disc-plastic-plastic-plunger-do/">Safety device &#8220;open&#8221;, brass disc, plastic, plastic plunger=DO</a> proviene da <a href="https://univalsrl.it/en/">Unival</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Double safety device &#8220;open&#8221; all in PA6=PP</title>
		<link>https://univalsrl.it/en/product/double-safety-device-open-all-in-pa/</link>
		
		<dc:creator><![CDATA[Enrico Sala]]></dc:creator>
		<pubDate>Fri, 03 Sep 2021 07:48:45 +0000</pubDate>
				<guid isPermaLink="false">http://univalsrl.it/double-safety-device-open-all-in-pa6pp/</guid>

					<description><![CDATA[<p>Function The pressure relief valves protect hot water storage heaters from internal overpressure. Furthermore, they restrict or prevent (according to requirements) water returning to main supply piping. Pressure relief valves essentially consist of 8 main devices: 3 controlling flow and 5 safety devices. The combination of these devices permits realisation which will satisfy customer&#8217;s requirements. [&#8230;]</p>
<p>L'articolo <a href="https://univalsrl.it/en/product/double-safety-device-open-all-in-pa/">Double safety device &#8220;open&#8221; all in PA6=PP</a> proviene da <a href="https://univalsrl.it/en/">Unival</a>.</p>
]]></description>
										<content:encoded><![CDATA[		<div data-elementor-type="product-post" data-elementor-id="5515" class="elementor elementor-5515 elementor-1771" data-elementor-post-type="product">
						<section class="elementor-section elementor-top-section elementor-element elementor-element-5fca0a3d elementor-section-boxed elementor-section-height-default elementor-section-height-default" data-id="5fca0a3d" data-element_type="section">
						<div class="elementor-container elementor-column-gap-default">
					<div class="elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-2f1bdda1" data-id="2f1bdda1" data-element_type="column">
			<div class="elementor-widget-wrap elementor-element-populated">
						<div class="elementor-element elementor-element-9766f7a elementor-widget elementor-widget-text-editor" data-id="9766f7a" data-element_type="widget" data-widget_type="text-editor.default">
				<div class="elementor-widget-container">
							<h2>Function</h2>
<p>The pressure relief valves protect hot water storage heaters from internal overpressure. Furthermore, they restrict or prevent (according to requirements) water returning to main supply piping. Pressure relief valves essentially consist of 8 main devices: 3 controlling flow and 5 safety devices. The combination of these devices permits realisation which will satisfy customer&#8217;s requirements.</p>
<h2>Safety devices</h2>
<h4>1. &nbsp; &nbsp; &nbsp; &nbsp;Water flow control device</h4>
<p>This device controls and runs passage of water from inlet source to water heater when <strong>on it’s inside the pressure become lower for 0,1±</strong><strong>0,2 bar (0,01&nbsp;</strong>±<strong>0,02 MPa),</strong> and in the same time it runs or pre vent water to go back into inlet source <strong>when the pressure inside water heater become higher for 0,8±</strong><strong>1,5 bar (0,08±</strong><strong>0,15 MPa)</strong>.</p>
<h4>2. &nbsp;&nbsp;&nbsp;&nbsp;Discharge pressure device ( Safety )</h4>
<p>The function of discharge pressure device is to avoid excessive pressure increment inside water heater. Calibration setting of discharge device is reached by compression of a spring to the standard <strong>value of opening 8,5 bar with tolerance ± 1 (0,85 MPa ±0,1)</strong>. This <strong>value can vary and</strong> <strong>be set according to the client&#8217;s request</strong>. The part is sealed with a disk to prevent tampering, and if the seal is tampered with and adjustment is made, it is not possible to open at pressures higher than 12 bar (1.2 MPa). During the testing the value of calibration setting is took on the second opening of discharge pressure device. During the discharge phase <strong>the device becomes watertight again when the pressure has decreased by 1 bar (0.1 MPa) with respect to the opening value 8.5 bar</strong> <strong>±</strong> <strong>1(0.85 MPa</strong> <strong>±</strong><strong>0.1).</strong> All valves are calibrated and tested automatically before being packed and we guaranty high quality standards constant in quantities and time.</p>
<h4>Valve body</h4>
<p>The body is made of hot moulded BRASS UNI EN 12165CW617N. Direction of the water flow. The surface is nickel &#8211; plated. Available (according to type) with threaded connections: 1/2 &#8221; -3/4 &#8221; -1 &#8221; Gas. The valve body is also designed to withstand internal pressures up to 16 bar (1.6 MPa). <strong>Maximum operating temperature of fully assembled valves: 120 ° C.</strong> The valve is automatically calibrated and checked during assembling. Further testing in percentage is carried out once assembling is finished.</p>
						</div>
				</div>
					</div>
		</div>
					</div>
		</section>
				</div>
		<p>L'articolo <a href="https://univalsrl.it/en/product/double-safety-device-open-all-in-pa/">Double safety device &#8220;open&#8221; all in PA6=PP</a> proviene da <a href="https://univalsrl.it/en/">Unival</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Safety device &#8220;simple open&#8221;, brass disc, plunger in PA6=PV</title>
		<link>https://univalsrl.it/en/product/safety-device-simple-open-brass-disc-plunger-pa/</link>
		
		<dc:creator><![CDATA[Enrico Sala]]></dc:creator>
		<pubDate>Fri, 03 Sep 2021 07:45:16 +0000</pubDate>
				<guid isPermaLink="false">http://univalsrl.it/safety-device-simple-open-brass-disc-plunger-in-pa6pv/</guid>

					<description><![CDATA[<p>Function The pressure relief valves protect hot water storage heaters from internal overpressure. Furthermore, they restrict or prevent (according to requirements) water returning to main supply piping. Pressure relief valves essentially consist of 8 main devices: 3 controlling flow and 5 safety devices. The combination of these devices permits realisation which will satisfy customer&#8217;s requirements. [&#8230;]</p>
<p>L'articolo <a href="https://univalsrl.it/en/product/safety-device-simple-open-brass-disc-plunger-pa/">Safety device &#8220;simple open&#8221;, brass disc, plunger in PA6=PV</a> proviene da <a href="https://univalsrl.it/en/">Unival</a>.</p>
]]></description>
										<content:encoded><![CDATA[		<div data-elementor-type="product-post" data-elementor-id="5511" class="elementor elementor-5511 elementor-1767" data-elementor-post-type="product">
						<section class="elementor-section elementor-top-section elementor-element elementor-element-f76ab72 elementor-section-boxed elementor-section-height-default elementor-section-height-default" data-id="f76ab72" data-element_type="section">
						<div class="elementor-container elementor-column-gap-default">
					<div class="elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-37f2642" data-id="37f2642" data-element_type="column">
			<div class="elementor-widget-wrap elementor-element-populated">
						<div class="elementor-element elementor-element-24881e0 elementor-widget elementor-widget-text-editor" data-id="24881e0" data-element_type="widget" data-widget_type="text-editor.default">
				<div class="elementor-widget-container">
							<h2>Function</h2>
<p>The pressure relief valves protect hot water storage heaters from internal overpressure. Furthermore, they restrict or prevent (according to requirements) water returning to main supply piping. Pressure relief valves essentially consist of 8 main devices: 3 controlling flow and 5 safety devices. The combination of these devices permits realisation which will satisfy customer&#8217;s requirements.</p>
<h2>Safety devices</h2>
<h4>&nbsp;&nbsp;&nbsp;&nbsp;1. Water flow control device</h4>
<p>This device controls and runs passage of water from inlet source to water heater when <strong>on it’s inside the pressure become lower for 0,1</strong>±<strong>0,2 bar (0,01&nbsp;</strong>±<strong>0,02 MPa),</strong> and in the same time it runs or pre vent water to go back into inlet source <strong>when the pressure inside water heater become higher for 0,8</strong>±<strong>1,5 bar (0,08</strong>±<strong>0,15 MPa)</strong>.</p>
<h4>&nbsp;&nbsp;&nbsp;&nbsp;2. Discharge pressure device (Safety)</h4>
<p>The function of discharge pressure device is to avoid excessive pressure increment inside water heater. Calibration setting of discharge device is reached by compression of a spring to the standard <strong>value of opening 8,5 bar with tolerance ± 1 (0,85 MPa ±0,1)</strong>. This <strong>value can vary and</strong> <strong>be set according to the client&#8217;s request</strong>. The device is sealed with disc to prevent from tampering. Should the seal be removed and the setting altered the maximum opening won&#8217;t be higher than 12 bar (1,2 MPa). During the testing the value of calibration setting is took on the second opening of discharge pressure device. During the phase of discharge, device becomes again watertight when the <strong>pressure decrease for 1 bar (0,1 MPa) in respect of standard opening value 8,5 bar</strong> <strong>±</strong><strong>1 (0,85 MPa</strong> <strong>±</strong><strong>0,1)</strong> All valves are calibrated and tested automatically before being packed and we guaranty high quality standards constant in quantities and time.</p>
<h4>Valve body</h4>
<p>The body is made of hot moulded BRASS UNI EN 12165CW617N. Direction of the water flow. The surface is nickel &#8211; plated. Available (according to type) with threaded connections: 1/2 &#8221; -3/4 &#8221; -1 &#8221; Gas. The valve body is designed to withstand internal pressure up to 16 bar (1,6MPa ). <strong>Maximum working temperature of the assembled valve : 120° C</strong>. The valve is automatically calibrated and checked during assembling. Further testing in percentage is carried out once assembling is finished.</p>
						</div>
				</div>
					</div>
		</div>
					</div>
		</section>
				</div>
		<p>L'articolo <a href="https://univalsrl.it/en/product/safety-device-simple-open-brass-disc-plunger-pa/">Safety device &#8220;simple open&#8221;, brass disc, plunger in PA6=PV</a> proviene da <a href="https://univalsrl.it/en/">Unival</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Safety device &#8220;simple closed&#8221;, all in PA6=PC</title>
		<link>https://univalsrl.it/en/product/safety-device-simple-closed-all-in-pa/</link>
		
		<dc:creator><![CDATA[Enrico Sala]]></dc:creator>
		<pubDate>Fri, 03 Sep 2021 07:41:53 +0000</pubDate>
				<guid isPermaLink="false">http://univalsrl.it/safety-device-simple-closed-all-in-pa6pc/</guid>

					<description><![CDATA[<p>Function The pressure relief valves protect hot water storage heaters from internal overpressure. Furthermore, they restrict or prevent (according to requirements) water returning to main supply piping. Pressure relief valves essentially consist of 8 main devices: 3 controlling flow and 5 safety devices. The combination of these devices permits realisation which will satisfy customer&#8217;s requirements. [&#8230;]</p>
<p>L'articolo <a href="https://univalsrl.it/en/product/safety-device-simple-closed-all-in-pa/">Safety device &#8220;simple closed&#8221;, all in PA6=PC</a> proviene da <a href="https://univalsrl.it/en/">Unival</a>.</p>
]]></description>
										<content:encoded><![CDATA[		<div data-elementor-type="product-post" data-elementor-id="5506" class="elementor elementor-5506 elementor-1766" data-elementor-post-type="product">
						<section class="elementor-section elementor-top-section elementor-element elementor-element-4962758c elementor-section-boxed elementor-section-height-default elementor-section-height-default" data-id="4962758c" data-element_type="section">
						<div class="elementor-container elementor-column-gap-default">
					<div class="elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-32fbae5b" data-id="32fbae5b" data-element_type="column">
			<div class="elementor-widget-wrap elementor-element-populated">
						<div class="elementor-element elementor-element-3dfc3b8 elementor-widget elementor-widget-text-editor" data-id="3dfc3b8" data-element_type="widget" data-widget_type="text-editor.default">
				<div class="elementor-widget-container">
							<h2>Function</h2>
<p>The pressure relief valves protect hot water storage heaters from internal overpressure. Furthermore, they restrict or prevent (according to requirements) water returning to main supply piping. Pressure relief valves essentially consist of 8 main devices: 3 controlling flow and 5 safety devices. The combination of these devices permits realisation which will satisfy customer&#8217;s requirements.</p>
<h2>Safety devices</h2>
<h4>&nbsp;&nbsp;&nbsp;&nbsp;1. Water flow control device</h4>
<p>This device controls and runs passage of water from inlet source to water heater when <strong>on it’s inside the pressure become lower for 0,1±</strong><strong>0,2 bar (0,01&nbsp;</strong>±<strong>0,02 MPa),</strong> and in the same time it runs or pre vent water to go back into inlet source <strong>when the pressure inside water heater become higher for 0,8±</strong><strong>1,5 bar (0,08±</strong><strong>0,15 MPa)</strong>.</p>
<h4>&nbsp;&nbsp;&nbsp;&nbsp;2. Discharge pressure device ( Safety )</h4>
<p>The function of discharge pressure device is to avoid excessive pressure increment inside water heater. Calibration setting of discharge device is reached by compression of a spring to the standard <strong>value of opening 8,5 bar with tolerance ± 1 (0,85 MPa ±0,1)</strong>. This <strong>value can vary and</strong> <strong>be set according to the client&#8217;s request</strong>. The device is sealed with disc to prevent from tampering. Should the seal be removed and the setting altered the maximum opening won&#8217;t be higher than 12 bar (1,2 MPa). During the testing the value of calibration setting is took on the second opening of discharge pressure device. During the phase of discharge, <strong>device becomes again watertight when the pressure decreases for 1 bar (0,1 MPa) in respect of standard opening value 8,5 bar</strong> <strong>±1</strong>(<strong>0,85 MPa</strong><strong>±</strong><strong>0,1).</strong> All valves are calibrated and tested automatically before being packed and we guaranty high quality standards constant in quantities and time.</p>
<h4>Valve body</h4>
<p>The body is made of hot moulded BRASS UNI EN 12165CW617N. Direction of the water flow. The surface is nickel &#8211; plated. Available (according to type) with threaded connections: 1/2 &#8221; -3/4 &#8221; -1 &#8221; Gas. The valve body is designed to withstand internal pressure up to 16 bar (±1,6MPa). <strong>Maximum working temperature of the assembled valve: 120° C.</strong> The valve is automatically calibrated and checked during assembling. Further testing in percentage is carried out once assembling is finished.</p>
						</div>
				</div>
					</div>
		</div>
					</div>
		</section>
				</div>
		<p>L'articolo <a href="https://univalsrl.it/en/product/safety-device-simple-closed-all-in-pa/">Safety device &#8220;simple closed&#8221;, all in PA6=PC</a> proviene da <a href="https://univalsrl.it/en/">Unival</a>.</p>